Przeglądanie stron 15
Setting
Item
L E D
state
Description Default
Door bell call tone 3-xx
Set the ring tone calling from door bell. Total 12
pieces ring tones can be selected(xx=01~12),press
Up button or Down button to increase/decrease
the value,settings will be performed immediately.
02
Ring volume 4-rx
Set the ring volume for call tone,range from 0~9.
6
Numbers of door
station
5-0x
Maximum 4 door stations can be selected,this
item is used to set the numbers of door station
that can be surveilled by indoor monitor. Refer to
part 2 ->Entrance Monitoring.
1
Numbers of
indoor monitor
6-xx
Maximum 32 indoor monitors can be selected,this
item is used to set the numbers of indoor monitor
that can be selected to intercom. Refer to part 2
->Intercom call.
04
Slave address
setting for monitor
7-dx
Rang from 0~3,"0"-master monitor,"1~3"-slave
monitor.
0
Restore to default
setting
8-FS
The restore to default function allows the user to
recover the settings to factory setting. Select "8-
FS" item on LED,then press Up button,"yES-
"will be asked,press Up button again,the LED
will be shown"SUCC",that means settings are
restored to default.
-
4. Specication
Power Supply: DC24V
Power Consumption: standby 25mA,working 110mA
7 segment LED: 4 digits dynamic
Wiring: 2 wires, non-polarity
Dimension: 187(H)X97(W)X33(D)mm
The design and specications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved.